Nano Accuracy, Every Needle Delivers Precision

Latest Collection
  • Magnetic Separation Aspirate Needle

    Precision magnetic-separation aspirate needle — inert low-binding bore prevents bead adsorption, dual external + through-needle wash for ultra-low carryover, OEM-grade drop-in fit and repeatable volume.

  • Coagulation Reagent Needle with stirring function

    Coagulation reagent needle with stirring function — dispensing and mixing in one probe, with OEM-true straightness and concentricity for uniform stirring, a fibrin-resistant 316L surface, and ultra-low carryover.

  • Chemiluminescence Sample Needle

    Precision CLIA sample needle — inert low-binding bore prevents residue, dual external + through-needle wash for ultra-low inter-sample carryover, OEM-grade drop-in fit and repeatable volume.

  • Reagent Needle for Sysmex-CA500

    Reagent needle for the Sysmex CA-500 series — compatible replacement for  P/N 663-0190-8. Precision reagent dispensing with a corrosion-resistant 316L bore, ultra-low carryover, and OEM-grade drop-in fit.

Testimonials

"After 8 months the tip was still true — no roll-over, no deformation — and our CBC QC cvs never moved."
fashion designer reviewer profile img 3
Marcus Reinhardt
"They seat at the cap-pierce station first time, the piercing is clean, and the aspirations are repeatable enough that nobody chases flagged results."
fashion designer reviewer profile img 2
Claire Beaumont
"Carryover between samples? Barely there anymore. The micro-clot blockages we used to fight — those don't happen now."
fashion designer reviewer profile img 4
Priya Raghavan
"Not once did a fibrinogen run need an extra wash cycle. Carryover stayed inside our limit. Fit was genuinely drop-in."
fashion designer reviewer profile img 1
Daniel Okafor

Nano Accuracy, Every Needle Delivers Precision&Endurance

Latest From The Blog
drop

Material & Surface Requirements

The internal bore must be extremely smooth, with minimal adsorption of biomolecules such as proteins and nucleic acids. This prevents analyte loss (falsely low results) and carryover between samples. The outer wall needs wear-resistant treatment too — plus low adsorption and easy cleaning. Chemically, the material must withstand acids, alkalis, and organic solvents. Corrosion or dissolution would contaminate the sample or inhibit the reaction. A tapered, thin-walled design helps empty the liquid completely, minimizing dead volume.

instrument 1

Piercing Probe Wear & Service Life

The piercing probe repeatedly pierces the rubber stopper of vacuum blood collection tubes, which wears on the needle. After too many punctures, the tip may lose its sharpness — or the aspiration orifice may deform. That's why piercing probes have a finite service life. They're consumables and must be replaced periodically. Extending probe life calls for a special wear-resistant coating. With a special alloy and a unique DLC (diamond-like carbon) coating, the probe is engineered for up to 100,000 punctures.

instrument 8

Accuracy, Liquid-Level Detection & Lot Consistency

Dispensed volume must match the nominal volume — the deviation has to be minimal. Even a small volume error shifts reaction concentrations. That's how false results creep in. Liquid-level detection is automatic. The tip never plunges too deep, never sucks air. Aspiration stays accurate. So does efficiency. Precision dimensions mean a stable, accurate fit in any automated analyzer — no wobbling, no misalignment. Every performance parameter must hold tight — within a lot, and across lots. That consistency is what makes results reliable and comparable.

Shopping Cart