Showing 1–18 of 22 results
-
Chemiluminescence Reagent Needle
Precision CLIA reagent needle — 316L inert, low-binding bore prevents adsorption and signal quenching; outer-wall coating plus dual external/through-needle wash drive carryover to ultra-low levels; OEM-grade drop-in fit and repeatable volume make it a reliable, cost-effective alternative.
-
Chemiluminescence Sample Needle
Precision CLIA sample needle — inert low-binding bore prevents residue, dual external + through-needle wash for ultra-low inter-sample carryover, OEM-grade drop-in fit and repeatable volume.
-
Chemiluminescence Trigger Solution Needle
Precision CLIA trigger solution needle — inert, corrosion-resistant bore that withstands acid and oxidizer, dual external + through-needle wash for ultra-low carryover, OEM-grade drop-in fit and repeatable volume.
-
Chemiluminescent Substrate Probe
Precision CLIA substrate probe — inert low-binding bore stops signal quenching, dual external + through-needle wash for ultra-low carryover, OEM-grade drop-in fit and repeatable volume.
-
Coagulation Reagent Needle with stirring function
Coagulation reagent needle with stirring function — dispensing and mixing in one probe, with OEM-true straightness and concentricity for uniform stirring, a fibrin-resistant 316L surface, and ultra-low carryover.
-
Hematology Analyzer Open Needle compatible
Hematology Analyzer Open Sampling Needle — purpose-built for open-vial (decapped) sampling: a mirror-polished Ra ≤ 0.02 μm bore, ≤ 0.05 mm straightness, optional liquid-level sensing and PTFE coating, and an OEM-grade drop-in fit that keeps carryover ultra-low.
-
Hematology Analyzer XS800i,XS1000i,XS500i
Sysmex XS-series (500i/800i/900i/1000i) compact 5-part analyzers use a piercing probe for closed-tube aspiration + dispensing from just 20 µL — ideal for pediatrics and oncology. Our compatible piercing probe (replaces OEM 051-0481-9, fits all XS models) matches OEM tip angle, edge sharpness, and bore: smooth piercing, precise aspiration/dispensing volume, zero-deviation timing.
-
Magnetic Separation Aspirate Needle
Precision magnetic-separation aspirate needle — inert low-binding bore prevents bead adsorption, dual external + through-needle wash for ultra-low carryover, OEM-grade drop-in fit and repeatable volume.
-
Pierce Needle for Sysmex Hematology Analyzer XE-5000
High-end Sysmex XT/XE 5-part analyzers (XT-1800i/2000i/4000i, XE-2100/5000) use a pierce needle for closed-tube + reagent-bottle sampling. Our compatible single-needle wear part fits all five models; machined to OEM geometry (XT pierce-unit assembly = OEM 971-0581-8): identical tip angle, edge sharpness, and bore — smooth piercing, precise aspiration/dispensing volume, zero-deviation timing.
-
Piercing Probe for Beckman Coulter LH series/HmX AL
Compatible Closed-Tube Piercing Probe for Beckman Coulter LH series and HmX AL — built to OEM geometry and tolerances for the closed-vial fluid path. Tip angle, edge sharpness and bore diameter match the original, keeping piercing smooth, aspiration volume precise and sampling timing on sequence — in a medical-grade 316L body with a surface-hardened tip, a mirror-polished bore, and OEM-grade dimensional consistency.
-
Piercing Probe for DxH 600 / 800 / 900
Compatible Piercing Probe for the Beckman Coulter DxH 600 / 800 / 900 — built to OEM geometry and tolerances as a replacement for OEM P/N B44886. Tip angle, edge sharpness and bore diameter match the original, keeping piercing smooth, aspiration volume precise and sampling timing on sequence — in a medical-grade 316L body with a surface-hardened tip, a mirror-polished bore, and OEM-grade dimensional consistency.
-
Pipette with Heater for CS-5100/CS-5100i
Pipette with heater for the Sysmex CS-5100/CS-5100i — Compatible Replacement for
D06104717.integrated heating holds a stable 37 °C for accurate clotting times, with a corrosion-resistant 316L bore, ultra-low carryover, and OEM-grade drop-in fit. -
Reagent Needle for Sysmex CS5100i
Reagent needle for the Sysmex CS-5100i — compatible replacement for P/N D06104717. Heated to a constant 37 ± 0.5 °C, with liquid-level sensing, a corrosion-resistant 316L bore, ultra-low carryover, and OEM-grade drop-in fit.
-
Reagent Needle for Sysmex-CA500
Reagent needle for the Sysmex CA-500 series — compatible replacement for P/N 663-0190-8. Precision reagent dispensing with a corrosion-resistant 316L bore, ultra-low carryover, and OEM-grade drop-in fit.
-
Reagent needle with heating element for Sysmex CA1500
Reagent needle with heating element for the Sysmex CA-1500 — compatible replacement for P/N 981-0181-1. Heated to a constant 37 ± 1.0 °C, with liquid-level sensing, a corrosion-resistant 316L bore, ultra-low carryover, and OEM-grade drop-in fit.
-
Sample Needle for Beckman Coulter
Sample Needle for DxH 500 —Open-Vial Aspiration Probe Compatible Replacement for B95837AA
12 µL Micro-Volume Precision
Wear-Resistant 316L Stainless Steel
Mirror-Polished Internal Bore
OEM-Grade Dimensional Tolerance
-
Sample Needle for KN21
Sample Needle for KN21- The compatible replacement (P/N 441-1634-7, fits KX-21 / KX-21N / XP-100 / XP-300) is machined to OEM geometry and tolerances: identical outer diameter, taper, bore, and tip angle for zero-drift aspiration volume and timing.
-
Sample needle for Sysmex Coagulation Analyzer CA7000
Sample needle for the Sysmex CA-7000 — precision cap-piercing and plasma aspiration with a low-binding 316L bore, ultra-low inter-sample carryover, and OEM-grade drop-in fit.